Click on the arrow to view more models 
HOT WATER
HIGH TEMPERATURE
CAPACITY
CHILLED WATER CIRCUIT
Flow Rate
Inlet / Outlet Temperature
Pressure Drop
COOLING WATER
Flow Rate
Inlet / Outlet Temperature
Pressure Drop
HOT WATER CIRCUIT
Flow Rate
Inlet / Outlet Temperature
Pressure Drop
POWER CONSUMPTION
DIMENSIONS
(Length/Width/Height )
OPERATING WEIGHT
    • MODEL
      HD10A CU
      169 KW   26.3 m³ / Hr 12.2/6.7 ° C 26 Kpa   48 m³ / Hr 29.4/34.8 ° C 47 Kpa   8.1 m³ / Hr 175/160 ° C 26 Kpa 5.7 KVA 2.7/1.6/2.1 m 4.1 Tons
    • MODEL
      HD 10B CU
      260 KW   40.6 m³ / Hr 12.2/6.7 ° C 33 Kpa   74 m³ / Hr 29.4/34.8 ° C 60 Kpa   12.4 m³ / Hr 175/160 ° C 36 Kpa 5.7 KVA 2.7/1.6/2.2 m 4.4 Tons
    • MODEL
      HD 10C CU
      359 KW   55.9 m³ / Hr 12.2/6.7 ° C 37 Kpa   102 m³ / Hr 29.4/34.8 ° C 72 Kpa   17.1 m³ / Hr 175/160 ° C 35 Kpa 5.7 KVA 2.7/1.6/2.2 m 4.5 Tons
    • MODEL
      HD 20A TCU
      450 KW   77.2 m³ / Hr 12/7 ° C 15 Kpa   120 m³ / Hr 29/34.6 ° C 21 Kpa   19.8 m³ / Hr 175/160 ° C 33 Kpa 7.8 KVA 3/2/2.6 m 4.6 Tons
    • MODEL
      HD 20B TCU
      540 KW   92.6 m³ / Hr 12/7 ° C 19 Kpa   150 m³ / Hr 29/34.3 ° C 24 Kpa   23.6 m³ / Hr 175/160 ° C 46 Kpa 7.8 KVA 3/2/2.6 m 4.9 Tons
    • MODEL
      HD 20C TCU
      680 KW   116.6 m³ / Hr 12/7 ° C 46 Kpa   170 m³ / Hr 29/34.9 ° C 50 Kpa   30 m³ / Hr 175/160 ° C 30 Kpa 7.8 KVA 3.8/2/2.6 m 5.9 Tons
    • MODEL
      HD 20D TCU
      800 KW   137.2 m³ / Hr 12/7 ° C 54 Kpa   190 m³ / Hr 29/35.2 ° C 47 Kpa   35 m³ / Hr 175/160 ° C 38 Kpa 7.8 KVA 3.8/2/2.6 m 6.4 Tons
    • MODEL
      HD 30A TCU
      980 KW   168.1 m³ / Hr 12/7 ° C 47 Kpa   240 m³ / Hr 29/35.1 ° C 44 Kpa   43.1 m³ / Hr 175/160 ° C 31 Kpa 9.1 KVA 4/2.2/2.7 m 8.1 Tons
    • MODEL
      HD 30B TCU
      1100 KW   188.7 m³ / Hr 12/7 ° C 51 Kpa   300 m³ / Hr 29/34.4 ° C 54 Kpa   48 m³ / Hr 175/160 ° C 38 Kpa 9.2 KVA 4/2.2/2.7 m 8.6 Tons
    • MODEL
      HD 30C TCU
      1300 KW   223 m³ / Hr 12/7 ° C 82 Kpa   350 m³ / Hr 29/34.6 ° C 40 Kpa   57 m³ / Hr 175/160 ° C 28 Kpa 9.2 KVA 4.7/2.2/2.7 m 10.2 Tons
    • MODEL
      HD 40A TCU
      1500 KW   257.3 m³ / Hr 12/7 ° C 76 Kpa   400 m³ / Hr 29/34.6 ° C 35 Kpa   66 m³ / Hr 175/160 ° C 23 Kpa 9.2 KVA 4.9/2.5/2.9 m 12.2 Tons
    • MODEL
      HD 40B TCU
      1650 KW   283 m³ / Hr 12/7 ° C 74 Kpa   455 m³ / Hr 29/34.4 ° C 36 Kpa   72.3 m³ / Hr 175/160 ° C 27 Kpa 11.4 KVA 4.9/2.5/2.9 m 12.7 Tons
    • MODEL
      HD 40C TCU
      1820 KW   312.2 m³ / Hr 12/7 ° C 79 Kpa   500 m³ / Hr 29/34.4 ° C 38 Kpa   79.7 m³ / Hr 175/160 ° C 25 Kpa 11.4 KVA 4.9/2.5/2.9 m 13.3 Tons
    • MODEL
      HD 50A TCU
      2000 KW   343 m³ / Hr 12/7 ° C 65 Kpa   550 m³ / Hr 29/34.4 ° C 34 Kpa   87.6 m³ / Hr 175/160 ° C 37 Kpa 13.5 KVA 5.1/2.7/3.2 m 15.4 Tons
    • MODEL
      HD 50B TCU
      2250 KW   386 m³ / Hr 12/7 ° C 66 Kpa   580 m³ / Hr 29/34.7 ° C 71 Kpa   98.7 m³ / Hr 175/160 ° C 44 Kpa 13.5 KVA 5.1/2.7/3.2 m 16.1 Tons
    • MODEL
      HD 60A TCU
      2600 KW   446 m³ / Hr 12/7 ° C 55 Kpa   720 m³ / Hr 29/34.3 ° C 52 Kpa   113.5 m³ / Hr 175/160 ° C 31 Kpa 13.5 KVA 6.7/2.9/3.4 m 25.7 Tons
    • MODEL
      HD 60B TCU
      2900 KW   497.4 m³ / Hr 12/7 ° C 59 Kpa   800 m³ / Hr 29/34.4 ° C 53 Kpa   126.5 m³ / Hr 175/160 ° C 38 Kpa 13.5 KVA 6.7/2.9/3.4 m 26.8 Tons
    • MODEL
      HD 60C TCU
      3300 KW   566 m³ / Hr 12/7 ° C 68 Kpa   900 m³ / Hr 29/34.4 ° C 59 Kpa   143.7 m³ / Hr 175/160 ° C 63 Kpa 18.5 KVA 7.9/2.9/3.4 m 31 Tons
    • MODEL
      HD 60D TCU
      3640 KW   624.3 m³ / Hr 12/7 ° C 73 Kpa   1000 m³ / Hr 29/34.4 ° C 61 Kpa   158.5 m³ / Hr 175/160 ° C 24 Kpa 18.3 KVA 7.9/2.9/3.4 m 32.6 Tons
    • MODEL
      HD 70A TCU
      4100 KW   703.2 m³ / Hr 12/7 ° C 59 Kpa   1100 m³ / Hr 29/34.5 ° C 55 Kpa   179 m³ / Hr 175/160 ° C 59 Kpa 20.4 KVA 7.9/3.2/3.8 m 37.7 Tons
    • MODEL
      HD 70B TCU
      4500 KW   771.8 m³ / Hr 12/7 ° C 61 Kpa   1240 m³ / Hr 29/34.4 ° C 59 Kpa   196.1 m³ / Hr 175/160 ° C 24 Kpa 20.4 KVA 7.9/3.2/3.8 m 39.5 Tons
    • MODEL
      HD 80A TCU
      5220 KW   895.3 m³ / Hr 12/7 ° C 54 Kpa   1437 m³ / Hr 29/34.4 ° C 54 Kpa   227.2 m³ / Hr 175/160 ° C 57 Kpa 20.4 KVA 8.1/3.6/4.1 m 47.7 Tons
    • MODEL
      HD 80B TCU
      5700 KW   977.7 m³ / Hr 12/7 ° C 58 Kpa   1519 m³ / Hr 29/34.5 ° C 55 Kpa   248.2 m³ / Hr 175/160 ° C 24 Kpa 20.4 KVA 8.1/3.6/4.1 m 49.7 Tons
    • MODEL
      HD 80C TCU
      6500 KW   1115 m³ / Hr 12/7 ° C 92 Kpa   1540 m³ / Hr 29/35.2 ° C 68 Kpa   283.5 m³ / Hr 175/160 ° C 65 Kpa 25.4 KVA 9.35/3.6/4.1 m 56.3 Tons
    • MODEL
      HD 80D TCU
      7000 KW   1200.6 m³ / Hr 12/7 ° C 96 Kpa   1800 m³ / Hr 29/34.7 ° C 72 Kpa   304.5 m³ / Hr 175/160 ° C 36 Kpa 25.4 KVA 9.4/3.6/4.1 m 58.8 Tons
© Thermax Europe Ltd. All rights reserved.